Product Description
Sartorius A Series Analytical Balance Digimatic Output Interface Cable
Send data to our GageMux® gage interface or other Digimatic devices
This FlashCable® gage interface is designed to change the output on the Sartorius A Series Analytical Balance to an output in Mitutoyo Digimatic format. The 25-pin male connector on the Advanced Systems & Designs FlashCable® gage interface connects to the 25-Pin female connector on the Sartorius Balance. This Sartorius Balance must be equipped with the optional Sartorius interface in order to communicate with this FlashCable® gage interface.
This FlashCable® gage interface is engineered to work with our GageMux® multiple-input gage interface or similar devices that recognize the Mitutoyo Digimatic signal. It does not obtain any power from the gage. When connected to the GageMux® gage interface, pin 9 of the 10-pin input port provides the power to the FlashCable® gage interface. On Digimatic interfaces other than our GageMux®, pin 9 of the 10-pin connector needs to provide 5vDC power to the FlashCable® interface.
The LED on the FlashCable® gage interface will turn GREEN to indicate that the FlashCable® is connected properly. The LED flashes RED when the data is being sent or a data request is triggered.
The data transfer can be triggered using any of the following methods:
-
Using the PRINT key on the Sartorius A Series Analytical Balance
-
Using our 300-1S in-line handswitch
-
Using a footswitch on the FlashCable® (not included)
-
Using the footswitch on the GageMux® USB or similar triggering method
-
Sending a gage read command from the computer to the gage
A detailed operation manual is included with this FlashCable® gage interface. Lifetime warranty against manufacturing defects. Six foot standard cable lengths. Special lengths are available upon request.
Advanced Systems & Designs normally sets the FlashCable® gage interface to the default settings for the Sartorius A Series Analytical Balance. To insure proper communication both the Sartorius A Series Balance and FlashCable® gage interface must be set to the same values. Refer to the Sartorius A Series Analytical Balance and optional interface operating instructions for more information on interface communication with peripheral devices.
Details:
-
Digimatic output FlashCable® interface for Sartorius A Series Analytical Balance
-
Sends data to GageMux® or other devices that recognize the Digimatic signal
-
Several options to trigger data
-
Special cable lengths available on request
-
Lifetime warranty against manufacturing defects